BATCH OPERATIONS

BatchReactorWorks

Explore reactor heat transfer, thermal circuits and overhead operations.

Simulates a stirred batch reactor over time: a thermal programme (heat, hold and cool through a jacket or coil, a utility loop and an external circuit) or a process recipe of up to 100 operations, from purging and filling through reflux, distillation and decanting to cooling and discharge.

Prices

RunsPrice
Configuration checks, verification, vessel records and charges1 credit
Batch runs of up to six simulated hours2 credits
Batch runs of more than six simulated hours5 credits
  • A run that fails because of its inputs, doesn't converge or runs out of time is free.
  • Cancelling a run is free, before or after it starts.
  • A fault on our side is never charged: the run is tried again automatically.

A credit costs 8p to 10p, depending on the pack. Credits don't expire. Packs and prices

Inputs and results

You enter

  • The vessel, agitator, wall and jacket or coil, or a vessel record
  • The batch: a liquid, a solvent mixture or a ThermoWorks fluid
  • Utilities, condenser, separator, receiver and control valves
  • The thermal programme, or the recipe's operations

You get

  • Temperature, inventory, vapour and distillate over the batch, played back on the vessel's diagram
  • Heat duties and the integrated energy balance
  • Control-valve travel and capacity checks
  • A calculation audit with equations and substituted values

Example: Batch results

Recipe complete

The reference recipe: a toluene and water batch boiled, refluxed, decanted and cooled in a lined reactor.

The starting case every new BatchReactorWorks case opens on, run by the engine on our servers and stored (engine 1.1.0 · data 1.0.0). Nothing is calculated in your browser, here or in the calculator. Exports and the other tools of a run need an account.

Recipe complete · 173.10 min

Batch temperature
25.00°C
Liquid + coupled wall
Batch inventory
0.0kg
0.0 L
Vapour / reflux
0.0 / 0.0kg/h
Condenser 0.0 kW
Collected distillate
0.00kg
Separator 0.00 kg
STEP 1 / 9 · IN PROGRESSInert / purge0.00 min elapsed · target 2.000 vol% O₂
SIMULATED SNAPSHOT · Inert / purget = 0.00 min
BATCH PROCESS · EQUIPMENT & LIVE INVENTORIESRecipe playback · step 1 · in progressVAPOUR 0.0 kg/hE-101 · BLOCK HXCW OUT 15.0 °CCW IN 15.0 °C5.0 m³/h0.00 kW · 5.0 m²0% area usedCONDENSER VENT · VACUUM TRAINE-105 · GLYCOL CHILLER1.0 m² · U 150 W/m²KGlycol -5.0 °C · 1.0 m³/h setV-104 · KO POT10 LP-103 · PUMPExhaustISOLATEDSealed KO drain → reactorVACUUM CONTROLVacuum train offdry screw · 100 m³/h effectivePressure hold / isolatedPump gas 0.000 Nm³/hVent HX / KO duty: unmodelled— °CV-102 · DEAN–STARKBypassed · holdup retainedLight 0.00 kgHeavy 0.00 kg25.0 °C · 1.0 LHoldup 0.00 kg · 0% fullREFLUX TO REACTOR0.0 kg/hReturn light phaseDISTILLATE0.0 kg/hDirect bypass0.00 kg75.0 L capacityV-103 · DISTILLATE RECEIVERLIQUID FEED · CLOSED0.0 kg/h · schematic stream colourN₂ supply 0.000 Nm³/hPCV-102 · headspace vent 0.000 Nm³/hPCV-101 · gas supplyXV-103 · PURGE BYPASS / RO-103CLOSED · 0.00 Nm³/h · Ø 6.43 mmCv 0.63 · 0.0% · ClosedCv 1.6 · 0.0% · ClosedGAS MANAGEMENT20.900 vol% O₂Starting inertSupply total 0.000 Nm³Vent total 0.000 Nm³ (all paths)Cycle 0 / 325.00 °C0.0 kg0.0 L · 1.013 bar absSensible heat transferR-101 · BATCH REACTORCONVENTIONAL SHELL JACKETP-101RETURN 25.0 °C12.00 m³/h · set circulationUTILITY SUPPLYMaintained hot supplyJacket 0.00 kW · supply 25.0 °CAGITATION & HEAT0 rpm · 0.00 kWNet to batch 0.00 kWAgitator stopped · level / rpm permissiveD 1.00 mH 0.76 mMATERIAL BALANCEDischarged 0.00 kgResidual 0.00e+0 kgHeadspace O₂ 20.900 vol%BATCH COMPOSITIONTOLUENE 0.00 wt%WATER 0.00 wt%

Batch temperature

Batch
133353729203569104138173°CTime (min)
Batch remaining
0.00kg
Receiver remaining
0.00kg
Separator holdup
0.00kg
Mass closure
4.55e-13kg

Temperature history

133353729203569104138173°CTime (min)

Batch

Heat flow to batch

Net duty to the batch and condenser duty. Positive heats the batch.

-83-36115810503569104138173kWTime (min)

NetCondenser

Liquid inventories

Batch / collected distillate / separator holdup

-408020032044003569104138173kgTime (min)

BatchCollected distillateSeparator holdup

Integrated energy balance

Batch + thermally coupled wall control volume

Integrated net thermal input11.382 kWh
Feed enthalpy1.635 kWh
Vapour out − reflux enthalpy in13.223 kWh
Discharged enthalpy0.001 kWh
Numerical energy residual-3.398e-3 J

Condenser heat removed: 13.162 kWh. This is a separate control volume and is not subtracted twice.

Pressure-purge bypass · XV-103 / RO-103

Fixed bore 6.430 mm · Cd 0.620 · sizing duty 40.00 Nm³/h · ΔP 2.0000 bar. Endpoint 1.0182 bara. Bypass gas discharged 5.5911 Nm³. 360 recorded blowdown snapshots. PCV-102 is excluded from bypass flow.

ṁ = Cd A P₁ / √(Rs T) × F(P₂/P₁, γ); choked below rcrit = [2/(γ+1)]^[γ/(γ−1)]. The isothermal vessel balance is dP/dt = −ṁ Rs T / V. Time is integrated along the falling pressure curve; O₂ mole fraction is unchanged by venting alone. Gas inventory closure uses the exact pressure change. No constant vent-flow demand is imposed during bypass blowdown.

NASA: compressible discharge and choking basis

Gas valve travel and capacity · whole recipe

Valve / trimRated CvPeak required CvPeak travelHigh travel / capacity limitedControlling dutyAssessment
PCV-101 · Linear0.63000.399463.4%0.00 / 0.00 minStep 1 · Inert / purge · 22.22 min
30.000 Nm³/h · 6.0133 → 3.0133 bara
Within capacity
Below trim range: 72.59 min
Finite-ΔP suggested Cv: 0.63
PCV-102 · Linear1.60000.261816.4%0.00 / 0.00 minStep 3 · Fill / charge · 28.38 min
0.864 Nm³/h · 1.0333 → 1.0133 bara
Within capacity
Below trim range: 0.03 min
Finite-ΔP suggested Cv: 0.4
Check every operation
ValveStep / operationPeak Cv demandPeak openingHigh travelCapacity limitedBelow range
PCV-1011 · Inert / purge0.399463.4%0.00 min0.00 min0.00 min
PCV-1012 · Inert gas blanket0.385661.2%0.00 min0.00 min0.00 min
PCV-1016 · Azeotropic phase withdrawal0.00200.3%0.00 min0.00 min21.36 min
PCV-1017 · Cool down0.00390.6%0.00 min0.00 min51.23 min
PCV-1018 · Discharge0.03084.9%0.00 min0.00 min0.00 min
PCV-1023 · Fill / charge0.261816.4%0.00 min0.00 min0.00 min
PCV-1024 · Fill / charge0.227014.2%0.00 min0.00 min0.00 min
PCV-1025 · Heat up0.15919.9%0.00 min0.00 min0.03 min

Checks use the existing imposed flow and pressure trajectory. High travel includes saturated demand; capacity-limited time is flagged interval duration. Below trim range means the requested flow is below rated Cv / rangeability; reliable throttling is not assumed. Recommendations apply to finite positive ΔP only and are not applied automatically.

Linear: Cv/Cv,rated = h. Equal percentage: Cv/Cv,rated = R^(h−1) over the controllable trim range. h is fractional travel. Zero demand closes the valve; below-range flow is flagged separately. Fixed xT, Fp = Z = 1. Vent gas approximates air plus selected inert gas; solvent vapour is excluded.

Emerson: inherent characteristics and rangeability

StepOperationStart minFinish minPressure / vacuumGas operationEndpoint
1Inert / purge0.0027.721.013 bar abs · normal3 cyclesReached
2Inert gas blanket27.7227.741.018 bar abs · normal1.68 s gas transitionReached
3Fill / charge27.7442.741.033 bar abs · normal—Reached
4Fill / charge42.7457.741.033 bar abs · normal—Reached
5Heat up57.7480.511.033 bar abs · normal—Reached
6Azeotropic phase withdrawal80.51101.871.033 bar abs · normal—Reached · Separator drained: 0.432 kg light → reactor; 0.498 kg heavy → receiver
7Cool down101.87153.101.033 bar abs · normal—Reached
8Discharge153.10163.101.033 bar abs · normal—Reached
9Discharge163.10173.101.033 bar abs · normal—Reached
Overhead model basis & limits
  • Existing wall, jacket, half-pipe and external-loop correlations are retained. Boiling uses the existing agitated-liquid film as a screening heat-input estimate; no nucleate-boiling enhancement, CHF or dryout correlation is claimed.
  • NRTL liquid activity + ideal vapour, 0.2–2 bar abs. Pure-property limits are enforced; phase solver is bounded to 1–149 °C. Missing binary parameters block calculation. ChemSep parameters do not provide audited temperature ranges here.
  • 52 ChemSep binary pairs are bundled for this solvent subset. Toluene/water uses an engineering NRTL fit (α = 0.2) to IUPAC/NIST LLE tie-lines at 1 °C intervals, 0–150 °C. It reproduces the tie-lines; this is not independent VLE validation.
  • Only binary toluene/water automatic LLE is enabled. Other mixtures require confirmed homogeneous liquid. No excess enthalpy, reaction kinetics, solids or gas solubility model.
  • Total condenser with specified rated U, countercurrent coolant and explicit sensible cooling area. No noncondensable-gas correction, pressure drop, fouling evolution or condenser holdup. Optional glycol vent condenser and KO pot are equipment specifications only; vent duty, carryover and liquid recovery are not calculated. Evacuation gas removal is calculated; vacuum capacity during boiling is not verified.
  • Separator is isothermal with two equal-volume compartments, equilibrium redistribution and overflow. No settling rate or carryover calculation. Separator contents remain in the overall mass inventory across steps.
  • Gas inventory starts as 20.9% O₂ air every run. Flow purge uses exponential perfect mixing; pressure and vacuum purge use whole cycles at absolute pressure ratios. Supply impurity is included. The default 0.5% O₂ target is a user endpoint, not a validated safe oxygen limit.
  • Heat-transfer coefficients use equivalent mixture properties; two-liquid agitated heat transfer is a screening approximation. Pressure is prescribed. Vacuum holds are ideal, use absolute pressure and persist across recipe steps until released. Pump-down uses constant effective speed and ultimate pressure, with free volume plus a piping allowance. Backfill and pressure-cycle times use configured normal gas flow. No leak, desorption, wet-vapour load or valve-capacity prediction. Blanketing includes liquid displacement and ideal-gas thermal breathing. Published reactor validation cases remain parked.

NRTL equations · ChemSep parameters via thermo · IUPAC LLE report, equations 3–4 and table 9

Calculation audit Equations, substitutions, results and source references for manual checking.

Step 1 · 0.00 min

Component and energy inventory

SolventBatch kgSeparator kgReceiver kgBatch wt%
TOLUENE0.000000.000000.000000.000
WATER0.000000.000000.000000.000

Total mass residual: 0.0000e+0 kg. Reactor energy residual: 0.0000e+0 J.

ΔH(batch + wall) = ∫Qnet dt + Hfeed − Hdischarge − Hvapour + Hreflux. Liquid enthalpy uses integrated pure-component cp and additive mass contributions. Bubble temperature and evaporated mass are solved together for each boiling step.

Condenser and reflux

Vapour 0.000 kg/h; reflux 0.000 kg/h; distillate 0.000 kg/h.

Condenser duty 0.000 kW; required/installed area 0.00%; coolant outlet 15.00 °C.

Arequired = Qlatent/(U × LMTDcondensation) + Qsensible/(U × LMTDcooling). Coolant outlet follows Q = ṁcpΔT. Reflux ratio in distillation is L/D; total reflux returns all condensate and decant returns only the selected phase overflow.

Vacuum pressure control

Vessel pressure: 1.0133 bar absolute. Vacuum train: off / isolated.

Explicit evacuation uses P(t) = Pu + (Pstart − Pu) exp(−Seff t/Vgas). Vgas is free vessel volume plus the fixed piping allowance based on initial free volume. Once reached, the vacuum hold is ideal. The existing NRTL bubble-point and material/energy balances use the operating pressure. The glycol vent condenser and KO gravity return are shown but receive no extra solvent recovery credit under the primary total-condenser assumption.

Gas operations and blanketing

O₂ 20.9000 vol%; gas volume including piping 1.0332 m³; phase Starting inert.

Flow purge: Q = V/t × ln[(Cstart−Csupply)/(Ctarget−Csupply)]. Required rate 0.0000 actual m³/h. Swing purge: N = ceil{ln[(Ctarget−Csupply)/(Cstart−Csupply)] / ln(Plow/Phigh)}. 3 full cycles; actual phase times derive from charging/vent rates and evacuation.

Evacuation: t = V/Seff × ln[(Pstart−Pu)/(Ptarget−Pu)]. Non-boiling, constant temperature, constant effective speed. Inert supply total 0.00000 Nm³; vent 0.00000 Nm³; vacuum exhaust 0.00000 Nm³. Nm³ reference: 0 °C, 1.01325 bar.

Blanket gas requirement follows Δn ∝ Δ(PV/T), including liquid displacement. Gas entering mixes with the retained headspace; outflow carries the current composition. Gas sensible heat, leaks, dissolved oxygen and solvent vapour displacement are excluded from this gas subsystem. The liquid thermal balance is unchanged.

Linde: Inerting in the chemical industry, §8 · Pump-down equation and effective pumping speed

Gas control valve sizing

PCV-101 supply: sizing Cv 0.3994 → rated Cv 0.63 (automatic, linear). PCV-102 vent: sizing Cv 1.0443 → rated Cv 1.6 (automatic, linear).

Auto-selection rounds up to a generic preferred Cv series at the design travel plus margin; it is not a manufacturer model or body size. Selection remains fixed during the run. Full-recipe checks appear in Results and Audit.

First actual vent: 1.0333 bara → 1.0133 bara; 25.00 °C; 0.864 Nm³/h; Cv 0.26177.

Cv = qN / [2120 P1 Y √(x / (M T Z))]; x = min(ΔP/P1, (γ/1.4)xT), Y = 1 − x/[3(γ/1.4)xT]. Pressures absolute in bar, temperature K, qN in Nm³/h. Fp = Z = 1. Initial vent sizing is not the maximum Cv needed near the end of depressurisation. Supply sizing uses the chosen charging flow at the highest planned purge/blanket pressure. Vapour content and attached fittings are excluded.

Emerson Control Valve Handbook, chapter 5

Export time series CSV

Methods

  • Batch-side heat transfer from impeller correlations; jacket, half-pipe and condensing-steam film coefficients; wall resistances in series
  • Explicit midpoint time steps, with energy closure checked
  • Vapour–liquid equilibrium by NRTL, and a liquid–liquid split for toluene and water
  • Steam saturation from IAPWS SR1-86

How every calculator is tested: Methods and validation.

Limits

  • One well-mixed Newtonian liquid: no reaction kinetics, solids or gas dispersion
  • The wall at batch temperature, and quasi-steady utility films
  • Boiling as a screening heat input: no nucleate boiling or dryout
  • Correlation constants are literature values, not fitted to your equipment

Results are screening estimates from the methods described. A competent engineer must check them before relying on them in design, safety or operating decisions.

How it is checked

Parity with the original
The engine is a port of the original standalone calculator, and reproduces it on 345 generated cases: every quantity within 10⁻¹² relative, except 11 groups of quantities with a recorded tolerance of its own, where the original's numerical methods amplify rounding (iterative solvers, finite differences, residuals near zero).
Validation against reference data
No published reference cases yet.
The original's own checks
The original's numerical checks: IAPWS saturation, water's latent heat, a worked jacket example, energy closure and the integrator against an exact solution.